Allegeny Wood Pellets Logo

    Overview Specifications

    The Multi-Heat Boiler comes complete with:
    Boiler
    Casing with insulation
    Fuel Hopper
    Worm conveyor and gear motor
    Blower
    Turbulators
    Ceramic insert
    Boiler control
    Pressure tank set for automatic burn back protection
    Overheat cooling coil
    Micro-switch for hopper and thermostatic retrograde combustion cut-out as well as internal electrical installation
    Cleaning tools

    Accessories:

    Thermostatic tempering valve
    Draft stabilizer for chimney/boiler flue outlet

    Suitable Fuels:

    Wood pellets
    Corn

    Installation Guidelines:

    The Multi-Heat Boiler must be installed in a room with sufficient air supply.
    The chimney draft must be at least 0.05" water column
    Local building codes must be followed
    Further installation and operational guidelines are available from TARM USA, Inc.

    Technical data:

    MULTI-HEATModel 1.5Model 2.5Model 4.0
    Operating temperature °F (°C)140-185 (60-85)140-185 (60-85)140-185 (60-85)
    Output (nominal) with wood pellets BTU/hr (kW)51200 (15)85300 (25)146700 (43)
    Output (nominal) with corn BTU/hr (kW)N/A85300 (25)146700 (43)
    Output (minimum) with wood pellets BTU/hr (kW)15700 (4.6)25600 (7.5)40950 (12)
    Output (minimum) with corn BTU/hr (kW)N/A25600 (7.5)40950 (12)
    Output (stand-by) recommended **approx. BTU/hr (kW)1700 (0.5)2700 (0.8)3300 (1.0)
    Smoke temperature at nom. output, wood pellets °F (°C)302 (150)356 (180)356 (180)
    Smoke temperature at nom. output, corn °F (°C)392 (200)392 (200)
    Smoke temperature at min. output,wood pellets *** °F (°C)212 (100)230 (110)230 (110)
    Smoke temperature at min. output, corn °F (°C)239 (115)239 (115)
    Fuel consumption at nom. output,wood pellets lbs/hr (kg/h)7.5 (3.4)12.6 (5.7)22 (10)
    Fuel consumption at nom. output, corn lbs/hr (kg/h)N/A13.2 (6.0)24.3 (11)
    Test pressure, boiler PSI (bar)58 (4.0)58 (4.0)58 (4.0)
    Approved fuel types:wood pellets, approx. 8% of moisture inch (mm)1/4-3/4 (5-20)1/4-3/4 (5-20)1/4-3/4 (5-20

    Installation data:

    MULTI-HEATModel 1.5Model 2.5Model 4.0
    A Depth - total inch (mm)56 1/2 (1435)62 1/8 (1578) 66 5/8 (1693)
    B Width - boiler inch (mm)19 3/4 (504)23 5/8 (600)23 5/8 (600)
    C Height inch (mm)45 7/8 (1165)58 1/8 (1475)58 1/8 (1475)
    D Width - hopper * inch (mm)19 3/4 / 35 1/323 3/8 / 39 1/223 3/8 / 39 1/2
     (504/904)(600/1000)(600/1000)
    Hopper volume ft 3 (litre) 7/12 1/212 1/4/2112 1/4/21
     (200/350)(360/600)(360/600)
    Height to Flue collar inch (mm)43 3/4 (1110)57 1/4 (1455)57 1/4 (1455)
    Flue pipe branch - external diameter inch (mm)5 1/8 (130)5 7/8 (150)5 7/8 (150)
    Weight - empty lbs (kg)750/849 1279/1500
     (340-385)(530-630)(580-680)
    Water contents Us gal. (liter)13 (50)33 (125)39 (150)